Oil supplying unit type /specifications and notes thereof:

A table of recommended specifications of oil supplying unit
| serial number |
recommended specs |
suited to machine-set total power (HP/Ps) |
remarks |
| |
|
heavy oil daily use cabinet tempt/ steam pressure/ heat conducting oil tempt |
|
| 1 |
0.6 |
600-1200 |
commonly used |
| 2 |
1.0 |
1200-3500 |
commonly used |
| 3 |
1.2 |
3500-5500 |
commonly used |
| 4 |
1.8 |
5500-8000 |
|
| 5 |
3.0 |
8000-13000 |
|
| 6 |
5.0 |
13000-20000 |
|
| 7 |
10.0 |
20000-40000 |
|
Table 1 for type/specs of marine soil supplying unit:
This company has developed and manufactured oil-supplying units of 15 standard types with 62 different specifications. For non-standard products like those with additional homogenizer, mixer, six-pump type, and combination unit of separate oil suppliers, the company will make exclusive design for the customer. Following are standard types and specs:
serial number |
name code type |
spec |
basic characteristics |
1 |
two-pump/four pump tempt control codeD22(4)XD22(4)2D22(4)3 |
0.6 |
1.auto tempt control // two pump or four pump 2. compound and mixed heating type: hot water heating as main heating and stepped electrical heating (auto control) as supplementary heating 3. complete set costs less investment4.suited to revamped vessel---- where boiler isdifficult to install and yet without boiler there will be no steam; guarantees supply of the ainengine’s heavy diesel oil or heavy fuel oil below 1500s of Redwood viscosity |
1.0 |
1.2 |
2 |
two-pump/four pump tempt control codeT22(4)2T22(4)3 |
0.6 |
1.auto temptcontrol, two or four-pump(C),semi auto filter, easy of maintenance2.Heating by steam or heat conducting oil3.auto neumatic control, of high reliability 4.cost effective? 5. empirical in temp setting6.Suited to heavy oil of heal diesel oil below 1500s of Redwood viscosity |
1.0 |
1.2 |
3 |
two-pump viscosity control code n222n223 |
0.6 |
auto temptcontrol,two or four-pump(C),semi auto filter, easy of maintenance2.Heating by steam or heat conducting oil3.auto pneumatic control,of high reliability4.cost effective5. empirical in temp setting6.Suited to heavy oil of heal diesel oil below 1500s of Redwood viscosity |
1.0 |
1.2 |
4 |
four pump tempt control code n242n243n244n246 |
0.6 |
1.four – pump type with auto viscosity control2.Heating by steam /heat conducting oil, semi auto filter easy of intenance,3.Electrical auto control4.Suited to high viscosity heavy oil, below 3500s of Redwood iscosityscale5.High degree of reliability, easy operation andsimple of maintenance, of them the 1.0、1.2、1.8pecifications are the most commonly used |
1.0 |
1.2 |
1.8 |
3.0 |
5 |
two-pump viscosity control with self-cleaning filter code N222N223N224 |
0.6 |
1.Two-pump auto viscosity control2.Heating by steam /heat conducting oil, fully automatic reverse flow filter cleaning, easy of operation3.Electrical auto control4.Heavy oil cabinet of daily use higher than the unit by over 2 m5.Suited to various kinds of heavy oil below 2500s of Redwood viscosity |
1.0 |
1.2 |
1.8 |
6 |
four-pump viscosity control with self-cleaning filter code N242N243N245N246N247N248 |
0.6 |
1:four-pump auto viscosity control2.Heating by steam /heat conducting oil, semi auto filter easy of maintenance
3.
Electrical auto control 4.Suited to various kinds of heavy oil below 3500s of Redwood viscosity |
1.0 |
1.2 |
1.8 |
3.0 |
5.0 |
10.0 |
Table 2 for type/specs of marine soil supplying unit:
| serial number |
name code type |
spec |
basic characteristics |
1 |
two-pump tempt control double heating |
0.6 |
1. two-pump auto tempt control 2. double heating with auto control , heating by steam/heat conducting oil and electrical heating, semi automatic filter easy of maintenance, 3. heating by steam/heat conducting oil with pneumatic control, electrical heating being stepped and with auto control, 4. heavy oil cabinet of daily use higher than the unit by 2m, 5.empirical tempt- setting6.high ratio of performance/price, suited to heavy oil below 2500s by Redwood viscosity scale |
1.0 |
1.2 |
2 |
four-pump tempt control double heating
|
0.6 |
1. four-pump auto tempt control2.double heating with auto control , heating by steam/heat conducting oil and electrical heating, semi automatic filter easy of maintenance, 3. heating by steam/heat conducting oil with pneumatic control, electrical heating being stepped and with auto control? 4. empirical tempt setting5.high ratio of performance/price, suited to heavy oil below 3500s by Redwood viscosity scale, recommended product, commonly used specs are 1.0, 1.2 and 1.8 |
1.0 |
1.2 |
1.8 |
3 |
two-pump viscosity control double heating |
0.6 |
1. two-pump auto viscosity control 2. double heating with auto control , heating by steam/heat conducting oil and electrical heating, semi automatic filter easy of maintenance, 3. heating by steam/heat conducting oil with pneumatic control, electrical heating being stepped and with auto control4. heavy oil cabinet of daily use higher than the unit by 2m,5. suited to heavy oil below 2500s by Redwood viscosity scale |
1.0 |
1.2 |
4 |
four-pump viscosity control double heating |
0.6 |
1. four-pump auto viscosity control2. double heating with auto control , heating by steam/heat conducting oil and electrical heating, semi automatic filter easy of maintenance,3.heating by steam/heat conducting oil with pneumatic control, electrical heating being stepped and with auto control4. suited to heavy oil of high viscosity below 4500s by Redwood viscosity scale5.high reliability, easy operation and easy of maintenance, most widely used specs are 1.0, 1.2 and 1.8, a recommended type. |
1.0 |
1.2 |
1.8 |
3.0 |
5 |
two-pump viscosity control double heating with self cleaning filter |
0.6 |
1. two-pump auto viscosity control 2. double- heating with auto control , heating by steam/heat conducting oil and electricity , fully automatic reverse flow filter easy of maintenance, 3. heating by steam/heat conducting oil with electric auto control, electrical heating being stepped and with auto control, 4. heavy oil cabinet of daily use higher than the oil supplying unit by 2m, 5. suited to heavy oil below 2500s by Redwood viscosity scale |
1.0 |
1.2 |
1.8 |
6 |
four-pump viscosity control double heating with self cleaning filter |
0.6 |
1.four-pump auto viscosity control 2. double heating with auto control , heating by steam/heat conducting oil and electricity , fully automatic reverse flow filter easy of maintenance, 3. heating by steam/heat conducting oil with electric auto control, electrical heating being stepped and with auto control4. suited to heavy oil below 4500s by Redwood viscosity scale |
1.0 |
1.2 |
1.8 |
3.0 |
5.0 |
10.0 |
| 7 |
four-pump viscosity control double heating with self cleaning filter of remote computerized control
|
1.0 |
1.four-pump auto viscosity control 2. double heating with auto control , heating by steam/heat conducting oil and electricity , fully automatic reverse flow filter easy of maintenance, 3. heating by steam/heat conducting oil with electric auto control, electrical heating being stepped and with auto control4. with selection etween primary site control and secondary remote computer control,computer crystal touch screen displaying all working status and switching5. a switching unit set will be ordered separately 6.suited to heavy oil of high viscosity, below 4500s of Redwood viscosity scale 7. high price and low performance /price ratio, suited to very demanding high-end market, normally not recommended |
1.2 |
1.8 |
3.0 |
5.0 |
10.0 |
How to select the type and place your order:
Where heavy oil cabinet of daily use has its bottom level vertically higher by 2 or over 2m than the bottom level of oil supplying unit installation, one may select the two-pump type oil supplying unit, as this unit has low pressure for the air depletion in oil mixing, which reduces the evaporating temp of the light substances and water content in the fuel oil in high tempt oil return pipe. Two-pump type suits fuel oil below 1500s by Redwood viscosity scale.
The tonnage of the vessel, or container number, type of vessel, kind of fuel oil the vessel is going to use, location of shipyard where the vessel is built, and its main routes of voyage
Number of main engines or aux engines that consume heavy oil, manufacturer of the engine, their power and routine operating load, low speed engine or medium speed engine
Setup of the heating equipment on board, whether or not equipped with steam/heat conducting oil fuel boiler, waste steam boiler, hot water boiler, waste gas heat conducting oil boiler or waste gas from fuel oil combination boiler etc. Parameters such as steam evaporation volume and evaporating pressure
Power supply mode: normally 380V/50Hz/3Φ; in special cases where 440V/60Hz/3Φ、220V/60Hz/3Φ or others are used the relevant situation will have to be given.
In principle it is not recommended to use the main heating setup as electrical heating of the oil supplying unit. It is selected only when there is no other heating source in the cabin. However, electric heating can be an aux standby source of heat.
Layout of machine cabin and oil cabinets (oil tank, sedimentation cabinet, daily use cabinet and dirty oil cabinet)
You will please provide above mentioned plant conditions for us to give reference in type selection of purpose of optimum working conditions.
Two choices are available of oil supplying unit structural layout: 3-D individual cabinet control mode and plane integrated control mode. Unless customer specifies otherwise, control setup will be flat integrated mode.
A comparison between the flat integrated control mode and the 3-D individual cabinet control mode

Compared with 3-D individual cabinet control mode, the flat integrated control mode has the following advantages:
type
item |
flat integrated control |
individual cabinet control |
basic setup |
fully identical |
fully identical |
equipment layout |
basically a planar layout |
basically a 3-D layout |
operability |
simple and clear by one look, one can learn to operate in the shortest time |
equipment maintenance somewhat more complicated, operation is relatively more difficult because of the seemingly complicatedness |
maintenance |
easy operation and maintenance, operators/maintenance crew are not usually seen as dirty or smeared |
less easy of operation and maintenance. In case pump above gets leaky, the equipment and pipeline below may get damaged. |
repairs |
open and flat layout makes it easy to maintain, replace or dismount |
Because of frames around operating, maintenance, repairs, replacing or dismounting are not very easy |
gravity center and vibration characteristics |
Low gravity center lowers the free end, thereby greatly reducing vibration and enhancing the reliability of the equipment |
Comparatively higher gravity center and greater vibration make stability and reliability somewhat inferior |
electrical layout |
adoption of independent branch lines greatly reduces the probability of electrical failure and makes it a lot easier for service and maintenance |
Concentrated cable laying in the framework and spread out electrical cabinets make wire connections more complicated, repairs and removal of cable/wire more difficult, resulting in less good reliability. |
outer dimensions |
An additional 250—400 lengthwise, with identical width and height |
comparatively less room taken |
lifting and installing |
comparatively difficult to lift and move, parts/components may get damaged |
easy and convenient to lift and handle, not liable to damage parts and components |
appearance |
simple and quietly efficient |
fullness and elegance |
man/machine functionality |
a more human product, easy to operate |
less easy |
Concluding from above, the company recommends the flat integrated control oil- supplying unit. Where customer so requires, the company will also provide 3-D individual cabinet control oil supplying unit.
|